Epic Code LAB10163 Proteinase 3 Antibody (PR3)
Test Name Alias
PR3 Antibody | Antineutrophil Cytoplasmic Antibodies | Wegener’s Granulomatosis | 193
Interface Order Alias
11550
Collection Instructions
Specimen Collection: Blood
Container(s): Gold Top (Serum Separator-SST Gel)
Preferred Volume to Collect: 5.0 mL
Minimum Volume to Collect: 2.0 mL
Neonate Volume to Collect: 2.0 mL
Capillary collect ok: Yes
Microtainer acceptable: Yes
Collection Instructions:
- Gently invert gold tube(s) 8 - 10 times to mix clot activator with blood.
- Specimen should be processed within 2 hours – See Processing Instructions.
Processing Instructions (Laboratory, Outpatient or Off-site collection)
Processed Specimen: Serum
Centrifuge/Spin: Yes
Aliquot: No
Processing Instructions:
- Allow blood to clot for 30 minutes in a vertical position and centrifuge within 2 hours.
Transport Temperature: Refrigerate
Rejection Criteria
Specimen not centrifuged within 2 hours
Specimen Stability
Ambient: 12 hours
Refrigerate: 7 days
Frozen: aliquot serum for longer storage
Laboratory Retention: 7 days
Test Frequency
Test performed Monday - Friday with usual TAT 1 to 3 days
Reference Range
Reference Range | ≤0.3 Al |
Comments
Below 0.4 U/ml Negative
0.4-0.9 U/ml Equivocal
1.0 or above U/ml Positive
If positive or equivocal, recommend ANCA test if not already performed, or if MPO/PR3 result is negative and ANCA associated diseases are clinically suspected. Additional physician order is required for ANCA test.
Performing Department
Immunochemistry
Performing Department Laboratory Location
Corewell Health Reference Laboratory, Grand Rapids, MI
Methodology
Multiplex Flow Assay
CPT
83516
CDM Code
3018351624
Epic Test ID
1230101064
LOINC
PR3 Ab: 46267-1
Mayo Access Code
SHO193
Reviewed Date
12/13/2022