Epic Code LAB1230002 Interleukin 2 Receptor, Soluble
Additional Codes
Mayo code: FIL2S
Performing Laboratory
ARUP LaboratoriesSpecimen Type
VariesSpecimen Required
Specimen Type: Serum
Container/Tube: Red
Specimen Volume: 1 mL
Serum:
Collection Instructions: Draw blood in a plain red-top tube(s), serum gel tube is acceptable. Spin down within 2 hours of collection and freeze immediately. Send 1 mL of serum frozen in a plastic vial.
Separate specimens must be submitted when multiple test are ordered.
Note: Cytokine levels may demonstrate diurnal variation. For longitudinal comparison, it is recommended that cytokine levels be determined at the same time of day.
COLLECTION NOTE: Volumes listed are in serum or plasma, draw approximately 2 1/2 times the requested volume in whole blood.
Specimen Minimum Volume
0.4 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Varies | Frozen | 365 days |
Reject Due To
Hemolysis | NA |
Lipemia | NA |
Icterus | NA |
Other | Contaminated or Heat-inactivated |
Day(s) Performed
Monday, Wednesday, Friday
Reference Values
175.3 pg/mL - 858.2 pg/mLÂ
Interpretation
Interpretive Information: Cytokines
Results are used to understand the pathophysiology of immune, infectious, or inflammatory disorders or may be used for research purposes.
Reporting Name
IL 2 Receptor, SolubleMethod Name
Quantitative Multiplex Bead Assay
CPT Code Information
83520
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
FIL2S | IL 2 Receptor, Soluble | 76039-7 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
FIL2S | IL 2 Receptor, Soluble | 76039-7 |