Sign in →

Epic Code LAB1230002 Interleukin 2 Receptor, Soluble

Additional Codes

Mayo code: FIL2S

Performing Laboratory

ARUP Laboratories

Specimen Type

Varies


Specimen Required


Specimen Type: Serum

Container/Tube: Red

Specimen Volume: 1 mL

 

 

Serum:

Collection Instructions: Draw blood in a plain red-top tube(s), serum gel tube is acceptable. Spin down within 2 hours of collection and freeze immediately. Send 1 mL of serum frozen in a plastic vial.

 

Separate specimens must be submitted when multiple test are ordered.

Note: Cytokine levels may demonstrate diurnal variation. For longitudinal comparison, it is recommended that cytokine levels be determined at the same time of day.

 




Laboratory Test Directory Note:

COLLECTION NOTE: Volumes listed are in serum or plasma, draw approximately 2 1/2 times the requested volume in whole blood.

Specimen Minimum Volume

0.4 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Varies Frozen 365 days

Reject Due To

Hemolysis NA
Lipemia NA
Icterus NA
Other Contaminated or Heat-inactivated

Day(s) Performed

Monday, Wednesday, Friday

Reference Values

175.3 pg/mL - 858.2 pg/mL   

Interpretation

Interpretive Information: Cytokines

 

Results are used to understand the pathophysiology of immune, infectious, or inflammatory disorders or may be used for research purposes.

Reporting Name

IL 2 Receptor, Soluble

Method Name

Quantitative Multiplex Bead Assay

CPT Code Information

83520

LOINC Code Information

Test ID Test Order Name Order LOINC Value
FIL2S IL 2 Receptor, Soluble 76039-7

 

Result ID Test Result Name Result LOINC Value
FIL2S IL 2 Receptor, Soluble 76039-7

Report Available

1 to 6 days

Test Classification

This test was developed and its performance characteristics determined by ARUP Laboratories.