Epic Code LAB1230142 Aspergillus Antigen, BAL
Test Name Alias
Aspergillus Antigen Level Aspergillus Galactomannan | 330
Interface Order Alias
1230142
Specimen Requirements
Specimen Type: BAL
Container/Tube: Sterile, screw-cap transport
tube
Volume: 3 mL
Minimum volume: 1.0 mL
Specimen Transport Temperature
Frozen
Special Instructions
Do not aliquot or open tube.
Specimen Stability
Frozen: Preferred for all specimen types. Contact Spectrum Health Laboratory Referrals Department at 616-267-2753 for questions on specimen acceptability
Test Frequency
Sent to reference laboratory, TAT up to 7 days.
Reference Range
The reference range is an index of <0.5. Numerical index values will be reported.
Patients with an index of ≥0.5 are considered to be positive for galactomannan antigen.
Patients with an index of <0.5 are considered to be negative for galactomannan antigen.
Specimens testing positive will be retested to confirm the positive result.
A reference Index Value of <0.5 has been shown to be appropriate for both serum and bronchial lavage specimen types.
Performing Department
Referral Send Outs
Performing Department Laboratory Location
Send Out to VIRACOR REF LAB
Methodology
The Aspergillus Galactomannan EIA assay is an immunoenzymatic sandwich microplate assay for the detection of Aspergillus galactomannan antigen in adult and pediatric CSF, bronch wash, BAL and serum samples. The assay uses EBA-2 monoclonal antibodies which detect Aspergillus galactomannan.
CPT
87305
CDM Code
3421437
Epic Test ID
1230101559
Beaker LOINC
Send Out test to Viracor, LOINC Unavailable
Reviewed Date
6/9/2023
Beaker Names
Beaker Procedure Name: ASPERGILLUS ANTIGEN,
BAL
Beaker Display Name: Aspergillus Antigen,
BAL
BEAKER TEST NAME:
ASPERGILLUS ANTIGEN BAL
BEAKER TEST REPORT NAME: Aspergillus Antigen BAL
Beaker Synonyms
VIRACOR 1609
Beaker Collection and Specimen Handling
BEAKER COLLECTION: +F
Beaker Location, Container and Temperature
VIRACOR FROZEN: STERILECONTAINER A (Preferred)