Epic Code LAB1230552 Food Allergy Nut Panel
Test Name Alias
allergen panel | allergy panel | ImmunoCAP | RAST | Allergen Profile
Interface Order Alias
1230552
Clinical Information
All allergens are reported down to a cutoff level of 0.10 kU/L. The significance of allergen specific IgE levels between 0.10 and 0.35 kU/L remains undefined. Cumulative levels of multiple allergen specific IgE antibodies may have an additive effect in producing clinical symptoms.
Individual allergen specific IgE antibody levels may not always correlate with severity of clinical symptoms. Results must be interpreted in the context of the clinical history and the patient’s symptom presentation. Quantitative IgE levels can serve to guide overall disease management by targeted trigger exposure reduction to identified allergens.
IgE antibody levels to allergens less than 0.10 kU/L do not exclude the possibility of an anaphylactic reaction to the allergen involved, since in vitro assays are indicators of previous sensitization rather than predictors of future response. IgE antibody levels must be interpreted in the context of the clinical history of the patient and the reaction history involved.
Panel Information
Almond | Hazelnut | Pecan |
Brazil nut | Macadamia nut | Pistachio |
Cashew | Peanut | Walnut nut |
Collection Instructions
Specimen Collection: Blood
Container(s): Gold Top (Serum Separator-SST Gel)
Preferred Volume to Collect: 1 full tube (5.0 mL)
Minimum Volume to Collect: 5.0 mL
Neonate Volume to Collect: 5.0 mL
Capillary collect ok? Yes
Microtainer acceptable: Yes
Collection Instructions:
- Gently invert gold tube(s) 8 – 10 times to mix clot activator with blood.
- Specimen should be processed within 2 hours – See Processing Instructions.
- 1 full tube per 15 allergens.
Processing Instructions (Laboratory, Outpatient or Off-site collection)
Processed Specimen: Serum
Centrifuge/Spin: Yes
Aliquot: No
Processing Instructions: Allow blood to clot for 30 minutes in a vertical position and centrifuge within 2 hours.
Transport Temperature: Refrigerate
Rejection Criteria
- Quantity not sufficient (QNS)
- Specimen not centrifuged within 2 hours
Specimen Stability
Ambient: 12 hours
Refrigerate: 7 days
Frozen: aliquot serum for longer storage
Laboratory Retention: 30 days
Test Frequency
Available Monday through Friday, usual TAT 1-3 days.
Reference Range
Each individual allergen:
Please use the “Related Tests” field below for Reference Ranges of each specific allergen.
Performing Department
Immunochemistry
Performing Department Laboratory Location
Corewell Health Reference Laboratory, Grand Rapids, MI
Methodology
ImmunoCAP® System Fluorescence Enzyme Immunoassay (FEIA)
CPT
86003 PER ALLERGEN
CDM Code
Unavailable
Epic Test ID
1230102171
Mayo Access Code
Unavailable
Resources
Additional Information
Lab Staff:
For 1 allergen: 0.3mL serum
For more than 1 allergen: (0.05 mL x number of allergens) + 0.25mL dead space
2 tubes per panel
Reviewed Date
3/4/2024