Epic Code LAB1230889 Mycoplasma Genitalium (Mgen) PCR
Test Name Alias
Mgen | M gen | M-gen | STI
Interface Order Alias
1230889
Clinical Information
Testing is performed using the Abbott Alinity m STI Assay for the qualitative detection of ribosomal RNA (rRNA) from Mycoplasma genitalium (MG) to aid in the diagnosis of MG infections in symptomatic and asymptomatic individuals. This assay is FDA cleared to test the following specimens collected with the Alinity m multi-Collect Specimen Collection Kit: vaginal swabs, endocervical swabs and male urine. Results for MG will be reported as Positive or Negative (presumed negative for Mycoplasma genitalium rRNA). For specimens receiving a result of Invalid, a new specimen should be collected.
Icons & Photos
SH/SHMG: Workday Order ITM-ITM-1190747
Non-SH: Supply form "STD Multi-Collection Kit"
Collection Instructions
Specimen Collection: Swab or Urine
Container(s): Alinity m Multi-Collect tube
COLLECTION INSTRUCTIONS SWAB OR URINE
Multiple specimen collection types. Submit only one:
Specimen Type: Female Genital Swab Alinity m Multi-Collect tube |
---|
- Specimens should be obtained with a swab using a speculum moistened with sterile warm water to facilitate collection.
- Lubricants other than water should not be used since they can be toxic to the organism.
- Discard disposable transfer pipette; it is not required for endocervical swab specimen collection
- Remove the sterile swab from the wrapper, taking care not to touch swab tip or lay it down on any surface
- Insert the white tip of the specimen collection swab into the endocervix canal.
- Gently rotate the swab for 15 – 30 seconds to ensure adequate sampling
- Withdraw the swab, carefully
- Handle the cap and tube carefully to avoid contamination, including the outside of the transport tube and cap. If necessary, change gloves.
- Unscrew the transport tube cap and immediately place the specimen collection swab into the transport tube so that the white tip is down.
- Carefully break the swab at the scored line on the shaft; use care to avoid splashing the contents
- Recap the transport tube. Ensure the cap seals tightly.
- Label the transport tube with sample ID, including date and time of collection.
- Transport to lab within 24 hours at room temperature or 14 days refrigerated.
Specimen Type: Male Genital Swab Alinity m Multi-Collect tube |
---|
- The patient must be instructed not to urinate at least 1 hour prior to sampling.
- Insert swab 2-4 cm into Urethra.
- Rotate swab for 3-5 seconds and withdraw swab.
- Insert swab into the Abbott multi-collect transport media. Snap off shaft of swab at the score line.
- Leave swab in tube. Cap tube and label specimen.
- Transport specimen within 24 hours at room temperature or 14 days refrigerated.
Specimen Type: Urine (First void) |
---|
Container(s): Sterile urine cup (with lid) or Alinity m multicollect sample kit
Preferred Volume to Collect: 30.0 mL
Minimum Volume to Collect: 10 mL if sterile cup is transported to lab; to fill line of Alinity m multicollect tube if transferred in office.
Aliquot: Yes - Transfer urine to Alinity m multicollect tube in office is preferred.
Collection Instructions:
- First void ("dirty") urine is included in this collection, this is collected before a UA specimen, if both are needed.
- Do not cleanse the genital area prior to specimen collection.
- Patient should not have urinated for at least one hour prior to sample collection.
- Follow directions above to obtain a first void urine specimen.
- Discard specimen collection swab, it is not required for urine specimen collection.
- Unscrew the transport tube cap, taking care not to spill the transport buffer within.
- Handle the cap and tube carefully to avoid contamination.
- Use the plastic transfer pipette to transfer urine from the collection cup into the transport tube until the liquid level in the tube falls within the clear fill window of the transport tube label or else a new specimen should be collected.
- Do not overfill. Slightly more than one full squeeze of the transfer pipette bulb may be required to transfer the necessary volume of urine specimen.
- Recap the transport tube carefully. Ensure the cap seals tightly.
- Label the transport tube with sample identification information, including date of collection. Take care not to obscure the fill window on the transport tube.
Transport Temperature: Ambient (room temperature) or Refrigerated
NOTE: Failure to collect a urine specimen, including the first part of the voiding, may decrease the sensitivity of this test. If the specimen cannot be delivered to the laboratory within a few hours after collection it should be stored and refrigerated until it can be delivered. Specimen must be received in laboratory for analysis within 24 hours of collection.
Specimen Type: Patient Self-Collect Swab |
---|
Self-collected vaginal swabs may be used as opposed to provider-collected swabs. Self-collected swabs are supported by current clinical guidelines as recent studies have shown their equivalence, if not superiority, in quality and their association with increased patient satisfaction.
NOTE: Self-collection must still take place in a healthcare setting and is not approved for at-home collection.
LINK: Self-Swab for Testing
LINK: References
Rejection Criteria
- Leaky specimen
- QNS
- Urines in sterile cup not received into lab within 24 hours.
- Gynecological specimens in ThinPrep PreservCyt Solution container
Specimen Stability
For Genital swabs:
- Ambient: 14 days 2oC -30oC in Alinity m multi-collect specimen container
- Refrigerate: 14 days 2oC – 30oC in Alinity m multi-collect specimen container
- Laboratory Retention: 7 days
For Urine:
If the urine is put directly in the Alinity m collection tube, the following applies:
- Ambient: 14 days 2oC – 30oC in Alinity m multi-collect specimen container
- Refrigerate: 14 days 2oC – 30oC in Alinity m multi-collect specimen container
- Laboratory Retention: 7 days
If only a urine cup is received
- Refrigerate: 24 hours
- Laboratory Retention: 24 hours
Test Frequency
Available Monday through Friday.
Usual TAT 1-3 days
Reference Range
Negative
Performing Department
Molecular Diagnostics
Performing Department Laboratory Location
Corewell Health Advanced Technology Laboratory (ATL), Grand Rapids, MI
Methodology
Polymerase chain reaction (PCR)
CPT
87563
CDM Code
3068756302
Epic Test ID
1230102557
LOINC
100706-1
Mayo Access Code
Current unavailable
Reviewed Date
6/22/2023
Updated Date
10/17/2024 - Important note. Rejection Criteria.