Epic Code LAB1231227 Adenosine Deaminase, Pericardial Fluid
Additional Codes
Interface Order ID: 1231227
Performing Laboratory
ARUP LaboratoriesSpecimen Type
Body FluidSpecimen Required
Specimen Type: Pericardial fluid
Collection Container/Tube: Leak-proof container
Submission Container/Tube: Plastic vial
Specimen Volume: 0.5 mL
Collection Instructions:
1. Centrifuge pericardial fluid specimen at ambient temperature.
2. Transfer 0.5 mL of fluid (supernatant) into a plastic vial and freeze.
3. Send frozen. Specimen must remain frozen until received at performing lab.
4. Indicate source on requisition.
Specimen Minimum Volume
0.2 mL
Specimen Stability Information
| Specimen Type | Temperature | Time |
|---|---|---|
| Body Fluid | Frozen (preferred) | 30 days |
| Refrigerated | 7 days |
Reject Due To
| Bronchoalveolar lavage (BAL) | Reject |
| Glass tubes | Reject |
| Turbid specimens | Reject |
| Whole blood | Reject |
Day(s) Performed
Tuesday, Thursday, Sunday
Reference Values
0-40 U/L
Clinical Information
Refer to https://ltd.aruplab.com/
Reporting Name
Adenosine Deaminase Pericardial FldMethod Name
Quantitative Spectrophotometry
CPT Code Information
84311
LOINC Code Information
| Test ID | Test Order Name | Order LOINC Value |
|---|---|---|
| FADDP | Adenosine Deaminase Pericardial Fld | 49760-2 |
| Result ID | Test Result Name | Result LOINC Value |
|---|---|---|
| Z5894 | Adenosine Deaminase Pericardial Fld | 49760-2 |