Epic Code LAB1231548 DOAC Screen
Interface Order Alias
Inpatient or Emergency Department Testing Only
Quick Collect
LOOK+LOOK
Transport whole blood at room temperature to the Laboratory promptly. If Unable/not possible see Lab Test Directory/Lab Catalog for further processing instructions.
Clinical Information
This assay is a screen for recent oral DOAC (Xa inhibitor) medication use, prior to starting
therapeutic heparin. It is not a DOAC (Xa inhibitor) drug level. Direct oral Anti Xa inhibitors
include Apixaban (Eliquis) and Rivaroxaban (Xaralto). DOAC screen testing should be negative,
<0.10. If positive, ≥ 0.10, provider and or pharmacy should consider switching to UFH anti-IIa for
monitoring heparin therapy for 72 to 96 hours depending on renal clearance.
Panel Information
DOAC Screen
Ordering Instructions
The DOAC Screen test should be ordered prior to initiating heparin therapy. Utilize if the presence of Direct oral Anti Xa inhibitors are suspected. Direct oral Anti Xa inhibitors include Apixaban (Eliquis) and Rivaroxaban (Xaralto).
Collection Instructions
Specimen Collection: Blood
Container(s): Blue top (3.2% Na. Citrate)
Preferred Volume to Collect: 2.7 mL (Full 2.7 mL blue tube)
Minimum Volume to Collect: 1.8 mL (Full 1.8 mL blue tube)
Neonate Volume to Collect: See minimum volume
Capillary collect ok? No
Microtainer acceptable: No
Collection Instructions:
-
Detailed instructions (link): Anticoagulant Correction for High Hematocrit
-
Detailed collection instructions (link): Blue Citrate Tube
- Specimen should be processed within 1 hour – See Processing Instructions below.
Processing Instructions (Laboratory, Outpatient or Off-site collection)
- Processed Specimen: Double Spun Platelet Poor Plasma
- Centrifuge/Spin: Yes
- Aliquot: Yes
- Processing Instructions:
- Detailed instructions (link): Preparing Platelet Poor Plasma
- Separate plasma into 2 - 3 aliquots, minimum of 0.5 mL each.
- Freeze aliquots in plastic transport tubes immediately.
- Transport Temperature:
- Ambient (up to 1 hour in whole blood state)
- Frozen (plasma only >1 hours)
Specimen Transport Temperature
Frozen
Rejection Criteria
- Hemolysis
- Specimen has been thawed
Specimen Stability
- Ambient whole blood state unspun: 1 hour
- Ambient spun: 4 hours
- Frozen: Aliquot and freeze double spun platelet poor plasma within 1 hour of collection
- Frozen at -70°C: 2 months
- Frozen at -20°C: 2 weeks
Test Frequency
Test run Daily. TAT 4 hours
Reference Range
<0.10 IU/mL
Performing Department
COAGULATION
Performing Department Laboratory Location
Corewell Health Reference Laboratory, Grand Rapids, MI
Corewell Health Big Rapids Laboratory, Big Rapids, MI
Corewell Health Blodgett Laboratory, East Grand Rapids, MI
Corewell Health Butterworth Laboratory, Grand Rapids, MI
Corewell Health Gerber Laboratory, Fremont, MI
Corewell Health Greenville Laboratory, Greenville, MI
Corewell Health Lakeland Laboratories, St. Joseph, MI
Corewell Health Ludington Laboratory, Ludington, MI
Corewell Health Pennock Laboratory, Hastings, MI
Corewell Health Reed City Laboratory, Reed City, MI
Corewell Health Zeeland Laboratory, Zeeland, MI
Corewell Health Lakeland St. Joseph Laboratory, St. Joseph, MI
Corewell Health Lakeland Niles Laboratory, Niles, MI
Methodology
Chromogenic Based Assay
CPT
85520
CDM Code
3058552002
Epic Test ID
123010922
Mayo Access Code
Not available
Reviewed Date
1/19/2024
Updated Date
9/8/2024 - Processing Instructions