Epic Code LAB1231943 Angiotensin Converting Enzyme, CSF
Test Name Alias
LAB3501 | ACE CSF | Quest: 34692 | ACE-CSF, Angiotensin Converting Enzyme, CSF
Interface Order Alias
1231943
Clinical Information
Angiotensin Converting Enzyme (ACE), CSF - ACE, CSF is useful in diagnosing patients with sarcoidosis involving the central nervous system (CNS) and meninges.
Specimen Requirements
Specimen Collection Criteria
Collect: 1.0 mL Cerebrospinal Fluid (CSF) in a sterile collection container. (Minimum: 0.2 mL)
Send specimen for processing immediately after collection.
Physician Office/Draw Specimen Preparation
Maintain specimen frozen (-20°C/-4°F or below) prior to transport.
In-Lab Processing
Maintain specimen frozen (-20°C/-4°F or below) prior to transport.
Specimen Transport Temperature
Transport: 1.0 mL CSF, frozen (-20°C/-4°F or below). (Minimum: 0.2 mL)
Rejection Criteria
- Specimens not collected and processed as indicated.
Specimen Stability
Specimen Stability for Testing:
Room Temperature (20-26°C or 68-78.8°F): 4 days
Refrigerated (2-8°C or 36-46°F): 7 days
Frozen (-20°C/-4°F or below): 60 days
Specimen Storage in Department Prior to Disposal:
Specimen retention time is determined by the policy of the reference laboratory. Contact the Send Outs Laboratory with any questions.
Test Frequency
Performed: Sunday, Tuesday, Thursday
Results available in 3-6 days.
Reference Range
≤15 U/L
Performing Department
Send Outs
Performing Department Laboratory Location
Sent to Quest Diagnostics- Wood Dale, IL
Methodology
Kinetic
CPT
82164
LOINC
Unavailable
Reviewed Date
11/2/2025
Orderable Regions
Send Outs