Epic Code LAB1231969 Adenosine Deaminase, RBC

Test Name Alias

LAB1231969 | XADEN | Quest: 3914 

Interface Order Alias

1231969

Clinical Information

Adenosine Deaminase, RBC - Adenosine Deaminase (ADA) deficiency is an autosomal recessive disorder of purine metabolism primarily affecting lymphocyte development, viability, and function. Affected individuals have less than 1 percent of normal ADA catalytic activity in red cell hemolysates. ADA deficiency is the cause of 20-30 percent of SCID cases. If the patient has been recently transfused, ADA deficiency may be masked; interpret results with caution. Heterozygotes cannot be identified by this test.

Specimen Requirements

Specimen Collection Criteria

Collect (preferred specimen): One Lavender-top EDTA tube.

Also acceptable: Pink (K2EDTA), or Green (sodium or lithium heparin)

 

Physician Office/Draw Specimen Preparation

Do not centrifuge. Maintain whole blood at room temperature (20-26°C or 68-78.8°F) prior to transport.

 

n-Lab Processing

Do not centrifuge. Maintain whole blood at room temperature (20-26°C or 68-78.8°F) prior to transport.

Specimen Transport Temperature

Transport: 4.0 mL whole blood, room temperature (20-26°C or 68-78.8°F) in original collection tube. (Minimum: 1.0 mL)

Rejection Criteria

  • Hemolyzed specimens.
  • Specimens not collected and processed as indicated.

Specimen Stability

Specimen Stability for Testing:

Room temperature (20-26°C or 68-78.8°F): 15 days
Refrigerated (2-8°C or 36-46°F): 15 days
Frozen (-20°C/-4°F or below): Unacceptable

Specimen Storage in Department Prior to Disposal:

Specimen retention time is determined by the policy of the reference laboratory. Contact the Send Outs Laboratory with any questions.

Test Frequency

Performed: Sunday, Tuesday, Thursday
Results available in 2-4 days.

Reference Range

400-900 mU/g Hb

Performing Department

Send Outs

Performing Department Laboratory Location

Sent to Quest Diagnostics- Wood Dale, IL

Methodology

Kinetic Spectrophotometry

CPT

82657

LOINC

Unavailable

Reviewed Date

11/2/2025

Orderable Regions

Send Outs