Epic Code LAB133 Transferrin, Blood Level
Test Name Alias
Transferrin Blood Level | 8153
Interface Order Alias
10484
Specimen Requirements
Specimen Collection: Blood
Container(s): 4.5 mL Mint Green Top (Lithium Heparin Gel) or 5.0 mL Gold Top (Serum Separator-SST Gel)
- Preferred Volume to Collect: 4.5 mL
- Minimum Volume to Collect: 1.0 mL
- Neonate Volume to Collect: 0.5 mL
- Capillary collect ok? Yes
- Microtainer acceptable: Yes
Collection Instructions:
- Fasting specimen preferred but not required
- After collection, gently invert tube 8-10 times.
- Specimen should be processed within 2 hours – See Processing Instructions.
Processing Instructions (Laboratory, Outpatient or Off-site collection)
Processed Specimen: Plasma or Serum
Centrifuge/Spin: Yes
Aliquot: Yes
Processing Instructions:
- Plasma is preferred specimen type
- Green Tube/Plasma: Centrifuge after collection.
- Gold Tube/Serum: Allow blood to clot for 30 minutes in a vertical position and centrifuge within 2 hours.
- Minimum plasma/serum volume: 0.5 mL
Transport Temperature: Refrigerate
Specimen Stability
Ambient: 8 hours
Refrigerate: 72 hours
Frozen: aliquot plasma/serum for longer storage
Laboratory Retention: 72 hours
Test Frequency
Available 24 hours, usual TAT 1 day.
Reference Range
200 - 360 mg/dL
Performing Department
Chemistry
Performing Department Laboratory Location
Corewell Health Reference Laboratory, Grand Rapids, MI
Corewell Health Big Rapids Laboratory, Big Rapids, MI
Corewell Health Gerber Laboratory, Fremont, MI
Corewell Health Kelsey Laboratory, Lakeview, MI
Corewell Health Ludington Laboratory, Ludington, MI
Corewell Health Pennock Laboratory, Hastings, MI
Corewell Health Reed City Laboratory, Reed City, MI
Corewell Health Greenville Laboratory, Greenville, MI
Corewell Health Zeeland Laboratory, Zeeland, MI
Corewell Health Lakeland St. Joseph Laboratory, St. Joseph, MI
Methodology
Immunoturbidimetric
CPT
84466
CDM Code
3018446601
Epic Test ID
1230101233
LOINC
Transferrin: 3034-6
Mayo Access Code
SHO8153
Reviewed Date
3/7/2024