Epic Code LAB178 Amylase, Body Fluid
Test Name Alias
Amylase Body Fluid | 8267 | AMY BFL
Interface Order Alias
10307
Ordering Instructions
Ascites, Peritoneal, Pericardial, Pleural Cavity (Left or Right) will be performed at Corewell Health Reference Laboratory West.
If your source does not match the above, please order a Reference Miscellaneous Test (LAB848) and list the desired test, specimen source and type.
Collection Instructions
Specimen Collection: Body Fluid
Container(s): Clear top tube, no additive
Preferred Volume to Collect: Full tube
Minimum Volume to Collect: 0.5 mL
Collection Instructions:
- Indicate source.
- Ascites, Pericardial, Peritoneal, Left or Right Pleural Cavity will be performed at Corewell Health Reference Laboratory West
- If your source does not match the above, please order a Reference Miscellaneous Test and list the desired test and specimen source and type.
Processing Instructions (Laboratory, Outpatient or Off-site collection)
- Transport Temperature: Refrigerate
Specimen Stability
Ambient: 8 hours
Refrigerate: 72 hours
Laboratory Retention: 7 days
Test Frequency
Available 24 hours, usual TAT 1 day.
Reference Range
Reference range information is not available.
Amylase Peritoneal Fluid: Values greater than or equal to three times (3x) a simultaneously analyzed serum value are considered abnormal in ascites of pancreatic origin. Other peritoneal and intestinal disorders may also cause elevation of amylase.
Amylase Pleural Fluid: Pleural fluid amylase greater than the upper limit of normal (ULN) for serum amylase or pleural fluid amylase/serum amylase ratio greater than or equal to 1.5-2.0 is abnormal. Abnormal pleural fluid amylase is seen in pancreatitis, esophageal rupture, gastroduodenal perforation or malignant effusions.
Comment applied to all Fluids: This test was developed and its performance characteristics determined by Corewell Health Laboratories. It has not been cleared or approved by the FDA. This test is used for clinical purposes. It should not be regarded as investigational or for research. The reference range and other method performance specifications have not been established for this body fluid. The test result must be integrated into the clinical context for interpretation.
Performing Department
Chemistry
Performing Department Laboratory Location
Corewell Health Reference Laboratory, Grand Rapids, MI
Methodology
Enzymatic colorimetric IFCC
CPT
82150
CDM Code
3018215001
Epic Test ID
1230100333
LOINC
Amylase BFL: 1795-4
Specimen Type: 66746-9
Reviewed Date
3/7/2024
Updated Date
3/14/2024 - Ordering instructions and Reference Range
5/20/2024 - Collection Container updated from Mint or Red to Clear