Epic Code LAB2111030 Codeine/Morphine Levels
Test Name Alias
Codeine/Morphine Blood Level | 4051
Interface Order Alias
10342
Collection Instructions
Specimen Collection: Blood
Container(s): Gray Top (Potassium Oxalate and Sodium Fluoride) or Red top (no additive)
Uscreen and iSCREEN POC (Point of Care) urine drug testing cups are acceptable but not preferred
Preferred Volume to Collect: 3.0 mL
Minimum Volume to Collect: 2.0 mL
Neonate Volume to Collect: 2.0 mL
Capillary collect ok? Yes
Microtainer acceptable? Yes
Collection Instructions:
- After collection, gently invert tube 8-10 times.
- Gray Top is preferred tube.
- Specimen should be processed – See Processing Instructions.
Processing Instructions (Laboratory, Outpatient or Off-site collection)
Processed Specimen: Plasma or Serum
Centrifuge/Spin: Yes
Aliquot: Yes
Processing Instructions:
- Gray top:
- Centrifuge after collection
- Pipette plasma into aliquot tubes
- Red top:
- When tubes are clotted (30-45 minutes), centrifuge specimens
- Pipette serum into aliquot tube
Minimum plasma/serum volume: 1.0 mL
Transport Temperature: Ambient
Specimen Stability
Ambient: 72 hours
Refrigerate: 7 days
Frozen: 14 days
Laboratory Retention: 7 days
Test Frequency
Available daily, usual TAT 1-3 days.
STAT TAT 6 hours.
Reference Range
Codeine Level 10 - 100 ng/mL
Morphine Level 21 - 65 ng/mL
Performing Department
Toxicology
Performing Department Laboratory Location
Corewell Health Reference Laboratory, Grand Rapids, MI
Methodology
Liquid Chromatography-Mass Spectrometry
This test was developed and its performance characteristics determined by Spectrum Health Toxicology Laboratory. It has not been cleared or approved by the FDA. The laboratory is regulated under CLIA as qualified to perform high-complexity testing. This test is used for clinical purposes. It should not be regarded as investigational or for research.
CPT
80361, G0480
CDM Code
3018036101
Epic Test ID
1230100511
LOINC
Codeine Lvl: 3506-3
Morphine Lvl: 3827-3
Mayo Access Code
SHO4051
Additional Information
Gold Top SST not acceptable
Reviewed Date
2/15/2023