Epic Code LAB2111263EU Endoscopy Ultrasound Fine Needle Aspiration, Cytology
Test Name Alias
Endoscopy Ultrasound FNA Cytology | EUS | 334 | FNA
Interface Order Alias
11637
Collection Instructions
Specimen Type: Fine Needle Aspiration (FNA)
Container/Tube: 2 slides and 1 tube
Collection Instructions:
- Place a drop of aspirated material on a glass slide (labeled with the patient's full name and date of birth or Spectrum Health MRN on the frosted end with a No. 2 lead pencil)
- Place second labeled slide on top of aspirated material and draw two slides apart.
- Immediately fix one slide with cytology fixative spray or place in container of 95% ETOH and allow the second slide to dry.
- The number of slides prepared will depend on the amount of material aspirated and the areas sampled
- Rinse any residual material in the syringe and needle into a tube containing sterile balanced salt solution and refrigerate or Cytolyt solution. NOTE: Once the needle and syringe come in contact with Cytolyt solution, a new needle and syringe must be used for additional passes.
- Label container with 2 patient identifiers, including patient's name and label with specimen source.
- Complete Fine Needle Aspiration portion of the Anatomic Pathology consultation form and send with specimen to the Cytology Lab. Indicate site and include pertinent clinical data on requisition.
- When transporting solution vials containing cells to the laboratory, make sure the vial is tightly sealed. Align the mark on the cap with the mark on the vial to prevent leakage.
Lab Staff Instructions
- If Cytology is closed, refrigerate in SHRL Lab Central
Specimen Stability
Storage Requirements:
CytoLyt solution: store the containers at 15o-30oC (59o -86oF) without cells. Cells in CytoLyt solution are preserved for 8 days at room temperature. For best results, transport specimen to laboratory immediately for processing. If there is a delay, refrigerate solution until it is delivered to the laboratory. This 8 days at room temperature time pertains to samples in minimum CytoLyt solution to sample ration of 1 part CytoLyt solution to 3 parts sample.
Test Frequency
Available Monday – Friday, usual TAT 24 – 48 hours (excluding weekends and holidays).
Reference Range
An interpretative report will be provided.
Performing Department
Cytology
Performing Department Laboratory Location
Spectrum Health Regional Laboratory (SHRL), Grand Rapids, MI
Methodology
Methodology not available at this time
CPT
88173
Corresponding professional fees will also apply
CDM Code
4138923
Epic Test ID
1230100691
Reviewed Date
4/7/2023