Epic Code LAB270 Discontinued: Sputum Culture
Test Name Alias
Culture Respiratory Sputum | 160 | Sputum Gram Stain
Interface Order Alias
50012
Icons & Photos
or
Sterile Container with screw-on lid
Collection Instructions
Specimen Type: Sputum
Container/Tube: Sterile container
Preferred Volume to Collect: 5.0 mL
Minimum Volume to Collect: 1.0 mL
Collection Instructions:
- Morning collection is preferred.
- Rinse mouth with water or saline prior to collection
- Collect four or five deep coughs in a sterile specimen container.
- Place cap on the container.
- Label with orders (include source: sputum).
- Deliver to lab immediately.
A Gram stain is performed for culture suitability. If the results of the Gram stain is consistent with saliva, the culture will be rejected.
Link: Patient Collection Instructions
Specimen Transport Temperature (Off-site collection)
Transport Temperature: Refrigerated
Specimen Stability
Refrigerate: 24 hours
Laboratory Retention: 4 days
Test Frequency
Available daily, usual TAT 2-3 days.
Reference Range
Normal Upper Respiratory Flora present or no bacteria isolated.
Performing Department
Microbiology
Performing Department Laboratory Location
Corewell Health Reference Laboratory, Grand Rapids, MI
Methodology
Manual
CPT
87070
CDM Code
3068707001
Epic Test ID
1230100567
Mayo Access Code
SHO50012
Reviewed Date
9/7/2023