Epic Code LAB3294 IgE Stachybotrys
Additional Test Codes
Viracor Test Code: 78210Y
Test Name Alias
allergen | ImmunoCAP | Stachybotrys chartarum Ab | 11780
Interface Order Alias
11611
Specimen Requirements
Specimen Type: Serum
Container/Tube: Gold Top (Serum
Separator-SST Gel)
Volume: 5 mL
Minimum volume: 0.5 mL serum
Collection Instructions: Allow specimen to clot
for 30 minutes and centrifuge within 2 hours
Specimen Transport Temperature
Ambient
Specimen Stability
Ambient: 7 days
Refrigerate: 4 weeks
Frozen: >4 weeks
Test Frequency
Available twice per week, usual TAT 1-3 days.
Reference Range
ImmunoCAP® Quantitative Scoring Guide:
Class | IgE (kU/L) | Comment |
0 | <0.10 | Negative |
0/1 | 0.10-0.34 | Equivocal/Borderline |
1 | 0.35-0.69 | Low Positive |
2 | 0.70-3.49 | Moderate Positive |
3 | 3.50-17.49 | High Positive |
4 | 17.50-49.99 | Very High Positive |
5 | 50.00-99.99 | Very High Positive |
6 | >99.99 | Very High Positive |
Performing Department
Referral Send Outs
Performing Department Laboratory Location
Send Out to VIRACOR REF LAB
Methodology
The ImmunoCAP® FEIA method
CPT
86003
CDM Code
4028998
Epic Test ID
1230100245
LOINC
Stachybotrys IgE: 29616-0
Mayo Access Code
SHO11611
Reviewed Date
6/9/2023