Epic Code LAB3420 IgE Egg White, Component Allergen Panel
Test Name Alias
allergen | ImmunoCAP|RAST| Allergy | Allergen panel | Allergen Profile | Component Allergen | 7002
Interface Order Alias
11717
Clinical Information
Component panel includes allergens: Ovomucoid (Gal d 1) and Ovalbumin (Gal d 2).
Consideration for baked tolerance and outgrowing allergy is best interpreted by board certified allergist with potential for in office challenge.
Collection Instructions
Specimen Collection: Blood
Container(s): Gold Top (Serum Separator-SST Gel)
Preferred Volume to Collect: Full tube (5 mL)
Minimum Volume to Collect: 2.0 mL
Neonate Volume to Collect: 2.0 mL
Capillary collect ok? Yes
Microtainer acceptable: Yes
Collection Instructions:
- Gently invert gold tube(s) 8 – 10 times to mix clot activator with blood.
- Specimen should be processed within 2 hours – See Processing Instructions.
- 1 full tube per 15 – 20 allergens.
Processing Instructions (Laboratory, Outpatient or Off-site collection)
Processed Specimen: Serum
Centrifuge/Spin: Yes
Aliquot: No
Processing Instructions: Allow blood to clot for 30 minutes in a vertical position and centrifuge within 2 hours.
Transport Temperature: Refrigerate
Rejection Criteria
- Quantity not sufficient (QNS)
- Specimen not centrifuged within 2 hours
Specimen Stability
Ambient: 12 hours
Refrigerate: 7 days
Frozen: aliquot serum for longer storage
Laboratory Retention: 30 days
Test Frequency
Available Monday through Friday, usual TAT 1-3 days.
Reference Range
<0.35 kU/L
Performing Department
Immunochemistry
Performing Department Laboratory Location
Corewell Health Reference Laboratory, Grand Rapids, MI
Methodology
ImmunoCAP® System Fluorescence Enzyme Immunoassay (FEIA)
CPT
86008
CDM Code
3028600801
Epic Test ID
1230100092
Mayo Access Code
SHO11717
Additional Information
Lab Staff:
For 1 allergen: 0.3mL serum
For more than 1 allergen: (0.05 mL x number of allergens) + 0.25mL dead space
1 tube per panel
Reviewed Date
3/4/2025
Updated Date
3/17/2024 – Reference Range (OEE)
10/18/2024 Reflex Information removed