Epic Code LAB3530 A1 Antigen
Test Name Alias
A1 Ag | 7057
Interface Order Alias
11782
Quick Collect
BB 2 SIGNERS
Icons & Photos
6 mL Pink Top (EDTA) | 3 mL Lavender Top (EDTA) |
Specimen Requirements
Specimen Collection: Blood
Container(s): 6 mL Pink Top (EDTA) or 3 mL Lavender Top (EDTA)
Preferred Volume to Collect: 6.0 mL
Minimum Volume to Collect: 1.0 mL
Neonate Volume to Collect: 0.5 mL
Capillary Collect Acceptable? Yes
Collection Instructions:
- Gently invert EDTA tube(s) 8 - 10 times after collection.
- BB 2 Signers: Specimens for Blood Bank must have 2 signatures on the specimen written in ink that is resistant to smearing:
- User ID's or initials of collectors/witnesses
- Outpatient collection: The patient may serve as witness and initial the tube label.
- Policytech reference #6476
- Specimen must be labeled in the presence of the patient with:
- Patient's first and last name
- Unique identification number (MRN)
- Date of collection
- If there is any question as to the validity of the specimen identification or an inconsistency between current and previous results, a new specimen must be collected.
- User ID's or initials of collectors/witnesses
Processing Instructions (Laboratory, Outpatient or Off-site collection)
Processed Specimen: Whole Blood EDTA
Centrifuge/Spin: No
Aliquot: No
Transport Temperature: Ambient or Refrigerate
Specimen Stability
Ambient: 24 hours
Refrigerate: 10 days
Laboratory Retention: 10 days
Test Frequency
Available 24 hours, usual TAT 1 day
Reference Range
Not available
Performing Department
Blood Bank
Performing Department Laboratory Location
Corewell Health Big Rapids Laboratory, Big Rapids, MI
Corewell Health Blodgett Laboratory, Grand Rapids, MI
Corewell Health Butterworth Laboratory. Grand Rapids, MI
Methodology
Tube Technique
CPT
86905
Epic Test ID
1230100280
Reviewed Date
2/1/2022