Epic Code LAB521 C-Peptide Level

Important Note

Method is Roche cobas Electrochemiluminescense Immunoassay.
Patient results determined by assays using different manufacturers for methods may not be comparable.

Test Name Alias

C-Peptide Level | Connecting Peptide of Insulin | 8288 | SHO8288 | 1230100527

Interface Order Alias

10114

Collection Instructions

Specimen Collection: Blood

 

Container(s): Gold Top (Serum Separator-SST Gel) or Light Green Top (Lithium Heparin Gel)

Minimum Volume to Collect: 1.0 mL

Neonate Volume to Collect: 0.5 mL

Capillary collect ok? Yes

Microtainer acceptable: Yes

 

Collection Instructions:

  • Fasting specimen preferred, but not required
  • After collection, gently invert tube 8-10 times.
  • Specimen should be processed within 2 hours See Processing Instructions.

 

Processing Instructions (Laboratory, Outpatient or Off-site collection)

  • Processed Specimen: Serum or Plasma
  • Minimum Volume Processed: 1.0 mL Serum or Plasma
  • Centrifuge/Spin: Yes
  • Aliquot: Yes
    • Serum is preferred specimen type
    • Green Tube/Plasma: Centrifuge after collection.
    • Gold Tube/Serum: Allow blood to clot for 30 minutes in a vertical position and centrifuge within 2 hours.
  • Transport Temperature: Refrigerated

Specimen Transport Temperature

Refrigerate

Specimen Stability

Ambient: 4 hours

Refrigerate: 24 hours

Frozen: aliquot plasma/serum for longer storage

Laboratory Retention: 72 hours

Test Frequency

Available 24 hours. Usual TAT 1 day.

Reference Range

0.9 - 4.3 ng/mL

Performing Department

Chemistry

Performing Department Laboratory Location

Corewell Health Reference Laboratory, Grand Rapids, MI

Methodology

Method is Roche cobas Electrochemiluminescense Immunoassay.
Patient results determined by assays using different manufacturers for methods may not be comparable.

CPT

84681

CDM Code

3018468101

Epic Test ID

1230100527

LOINC

C-peptide: 1986-9

Mayo Access Code

SHO8288

Reviewed Date

3/7/2024

Updated Date

3/28/2024 - Reference Range correction

12/2/2025 - Gold Top Preferred specimen

Orderable Regions

Southwest; West