Epic Code LAB706 Angiotensin Converting Enzyme (ACE) Level
Test Name Alias
Angiotensin Converting Enzyme Level | ACE | Kinase II | Peptidylpeptide Hydrolase | 8064
Interface Order Alias
10086
Specimen Requirements
Specimen Collection: Blood
Container(s): 5.0 mL Gold Top (Serum Separator-SST Gel)
- Preferred Volume to Collect: 5.0 mL
- Minimum Volume to Collect: 2.0 mL
- Neonate (NICU) Volume to Collect: at least 1 full microtainer
- Capillary collect ok? Yes
- Microtainer acceptable: Yes
Collection Instructions:
- Gently invert 8 - 10 times to mix clot activator with blood.
- Specimen should be processed within 2 hours – See Processing Instructions.
Processing Instructions (Laboratory, Outpatient or Off-site collection)
- Processed Specimen: Serum
- Centrifuge/Spin: Yes
- Aliquot: Yes
- Processing Instructions:
- Allow blood to clot for 30 minutes in a vertical position and centrifuge within 2 hours.
- Minimum serum volume: 1.0 mL serum
- Transport Temperature: Refrigerated
Specimen Stability
Ambient: 8 hours
Refrigerate: 72 hours
Frozen: aliquot serum for longer storage
Laboratory Retention: 72 hours
Test Frequency
Available daily, usual TAT 1 day.
Reference Range
Male/Female
0 Minutes up to 18 Years: 29-112 U/L
18 Years and up: 16/85 U/L
Performing Department
Chemistry
Performing Department Laboratory Location
Corewell Health Reference Laboratory, Grand Rapids, MI
Methodology
Spectrophotometric
CPT
82164
CDM Code
3018216401
Epic Test ID
1230100339
LOINC
ACE: 2742-5
Mayo Access Code
SHO8064
Reviewed Date
3/7/2024