Epic Code LAB71 IgG

Test Name Alias

Immunoglobulin G Blood Level | IgG Blood Level | 8212

Interface Order Alias

10177

Specimen Requirements

Submit only one of the following specimens:


Preferred

Specimen Type: Serum
Container/Tube: Gold Top (Serum Separator-SST Gel)
Volume: 5 mL
Minimum volume: 1.0 mL serum
Collection Instructions: Allow specimen to clot for 30 minutes and centrifuge within 2 hours

 


Acceptable
Specimen Type: Plasma
Container/Tube: Mint Green Top (Lithium Heparin Gel)
Volume: 4.5 mL
Minimum volume: 1.0 mL plasma
Collection Instructions: Centrifuge within 2 hours

Specimen Transport Temperature

Refrigerate

Specimen Stability

Ambient: 12 hours

Refrigerate: 72 hours

Frozen: aliquot serum for longer storage

Laboratory Retention: 72 hours

Test Frequency

Available daily, usual TAT 1 day.

Reference Range

Male/Female
0  up to 1 Month: 700 – 1400 mg/dL
1 Month up to 1 Year: 200 – 800 mg/dL
1 Year up to 4 Years: 400 – 1200 mg/dL
4 Years up to 10 Years: 600 – 1400 mg/dL
10 Years and up: 700 – 1500 mg/dL

Performing Department

Chemistry

Performing Department Laboratory Location

Corewell Health Reference Laboratory, Grand Rapids, MI
Corewell Health Lakeland St. Joseph Laboratory, St. Joseph, MI

Methodology

Immunoturbidimetric

CPT

82784

CDM Code

3018278403

Epic Test ID

1230100831

LOINC

IgG: 2465-3

Mayo Access Code

SHO8212

Reviewed Date

3/7/2024