Epic Code LAB862 Thiocyanate Level
Test Name Alias
Thiocyanate Blood Level | 8333
Interface Order Alias
10261
Clinical Information
A thiocyanate level is included with a blood cyanide order.
Collection Instructions
Specimen Collection: Blood
Container(s): Gray Top (Potassium Oxalate and Sodium Fluoride) or Red top (no additive)
Preferred Volume to Collect: 3.0 mL
Minimum Volume to Collect: 2.0 mL
Neonate Volume to Collect: 2.0 mL
Capillary collect ok? No
Microtainer acceptable? No
Collection Instructions:
- After collection, gently invert tube 8-10 times.
- Gray Top is preferred tube.
- Specimen should be processed – See Processing Instructions.
Processing Instructions (Laboratory, Outpatient or Off-site collection)
- Processed Specimen: Plasma or Serum
- Centrifuge/Spin: Yes
- Aliquot: Yes
- Processing Instructions:
- Gray top:
- Centrifuge after collection
- Pipette plasma into aliquot tubes
- Red top:
- When tubes are clotted (30 minutes), centrifuge specimens
- Pipette serum into aliquot tube
- Gray top:
- Minimum plasma/serum volume: 1.0 mL
- Transport Temperature: Ambient
Specimen Stability
Ambient: 72 hours
Refrigerate: 7 days
Frozen: 14 days
Laboratory Retention: 7 days
Test Frequency
Available 24 hours, usual TAT 1 day.
STAT TAT 2 hours.
Reference Range
- Non-smoker 1 to 4 µg/mL
- Smoker 3 to 12 µg/mL
- Toxic greater than 100 µg/mL
- Nitroprusside treatment 6 to 29 µg/mL
Performing Department
Toxicology
Performing Department Laboratory Location
Corewell Health Reference Laboratory, Grand Rapids, MI
Methodology
Colorimetric
This test was developed and its performance characteristics determined by Spectrum Health Toxicology Laboratory. It has not been cleared or approved by the FDA. The laboratory is regulated under CLIA as qualified to perform high-complexity testing. This test is used for clinical purposes. It should not be regarded as investigational or for research.
CPT
84430
CDM Code
3018443001
Epic Test ID
1230101211
LOINC
Thiocyanate Lvl: 3001-5
Reviewed Date
2/15/2023
Transport Temperature
Ambient
Updated Date
12/27/2023 - Collection Instructions